24 MDS 4710/9710 I/O Guide MDS 05-3305A01, Rev. D
HREV
Hardware Revision This command displays the transceiver’s hardware revision level. If
nothing is displayed, the hardware revision level was not programmed
by the factory.
INIT
Initialize EEPROM
Defaults
The INIT command is used to re-initialize the radio’s operating parame-
ters to the factory defaults. This is helpful when trying to resolve con-
figuration problems that might have resulted from the entry of one or
more improper command settings. If you are unsure of which command
setting caused the problem, this command allows you to get back to a
known working state. The following changes to the radio are made when
INIT is entered:
CTS is set to 0
DATAKEY is set to ON
DEVICE is set to DCE
PTT is set to 0
SCD is set to 0
TOT is set to 30 seconds and set to ON
PWR is set to +37 dBm (5 watts)
All other commands stay in the previously established setting.
INIT [4710/9710]
Packaged Model
Initialization
This command sets the transceiver for “normal” operation outside the
P-20 chassis by setting the following parameters to the values shown
below:
ASENSE ACTIVE HI
AMASK FFFF FFFF
(assert alarm output on all alarms)
RXTOT NONE (receive time-out timer disabled)
Use this command can to restore these three parameters to the standard
transceiver defaults if it was used in a P20 package.
INIT [4720/9720]
This command sets the transceiver for service within a P-20 by setting
the following parameters to the values shown below:
ASENSE ACTIVE LO
AMASK FFFF 0000
(trigger on major alarms)
RXTOT 20 (20 minute time-out timer)